Measurement for the systems you run.

Heating and cooling in buildings, coolant at the CDU, water supply and industrial lines. For each system: what to measure, how the meters connect and which models fit.

01 · Buildings & HVAC

Know what your heating and cooling circuits use.

Track water flow and heating or cooling energy.

  • Water flow in chilled-water and heating-water pipework.
  • Heating or cooling energy from the flow plus the supply and return temperatures.
  • Readings over the network straight into your own systems, or to MeterTube with the PoE and WiFi models.
What you can measure
  • Liquid flow
  • Flow and thermal energy
How the models connect
  • PoE / Ethernet
  • RS485 / 4–20 mA
  • LoRaWAN
  • Pulse / relay
  • WiFi
How the models install
  • Clamp-on
  • Clamp-on or insertion
Not confirmed yet for D106E, D114, E5, E8, F5, F8, VF600

Field installations

2 sites, photographed on site

Models for Buildings & HVAC

22 models

02 · Data center cooling

Coolant flow at the CDU.

Monitor coolant flow at the CDU in liquid-cooling systems.

  • Coolant flow at the coolant distribution unit (CDU) of a liquid-cooling system.
  • Wired into the controls over Modbus RS485 or as a 4–20 mA signal.
  • Confirmed per project the interface, pipe and coolant are checked with an engineer.
What you can measure
  • Liquid flow
How the models connect
  • RS485 / 4–20 mA
How the models install
  • Clamp-on
Not confirmed yet for D2, D5

Models for Data center cooling

3 models

03 · Water & industry

See what moves through your water lines.

Measure flow in water supply and industrial systems.

  • Supply, treated and production water in water networks, plants and production lines.
  • Continuous monitoring with a fixed meter on the line.
  • Surveys and checks with a portable meter for temporary measurement.
What you can measure
  • Liquid flow
  • Flow and thermal energy
How the models connect
  • PoE / Ethernet
  • RS485 / 4–20 mA
  • LoRaWAN
  • On-device storage
  • WiFi
  • Pulse / relay
How the models install
  • Clamp-on or insertion
  • Clamp-on
Not confirmed yet for F5E, D106E, D114, D348D Plus, E5, E8, F5, F8, GF-S-CL, GFCL, MFCL, VF600

Field installations

6 sites, photographed on site

Models for Water & industry

27 models

Before you choose

Start with your system conditions.

Pipe, liquid and connection decide which meter and sensor setup fits. You do not need a model number to get started.

Your pipe

Outside size, wall thickness, material, and whether it has a lining inside.

Your liquid

What flows through it, and at what temperature.

Your system

The power available at the meter and the data connection you need.

Tell us about your system.

Share your pipe, liquid and the connection you need. An engineer will help you choose the measurement approach and configuration.

Talk to an Engineer